Effect of building importance factor on seismic performance of rc frame type shopping malls subjected to pulse-like records

dc.contributor.authorGüllü, Ahmet
dc.contributor.authorKarameşe, Genco
dc.date.accessioned2024-06-13T20:18:01Z
dc.date.available2024-06-13T20:18:01Z
dc.date.issued2021
dc.departmentFakülteler, Mühendislik Fakültesi, İnşaat Mühendisliği Bölümü
dc.description.abstractSince they offer many alternatives for shopping, eating, resting, etc. many people spend a considerable time in shopping mall buildings. Therefore, this type of building is increasing rapidly. The increment rate was almost three in Turkey for the last decade. The recently released seismic code of the country has some serious alterations such as increased seismicity of some regions and reduced performance level limits of structural members. Besides, the building importance factor (I) of the shopping malls was defined clearly to be 1.2 whereas some shopping malls were designed considering I = 1.0 and constructed before 2018. Therefore, seismic performances of the shopping malls became questionable according to the code. In this study, seismic performances of two existing shopping mall buildings, which were designed and constructed by considering I = 1.0, are investigated based on the recently released seismic code and nonlinear analyses in which the utilized records were scaled considering I = 1.2. The results showed that the increased seismicity and reduced performance level limits may lead to excessive story drifts and plastic rotations for some records. However, the mean value of the analysis results satisfies the life safety (LS) performance level. Therefore, the importance factor might be suggested to be 1.0 for shopping malls close to the faults to avoid an unnecessary increment of the initial cost.
dc.identifier.doi10.1016/j.istruc.2021.07.075
dc.identifier.endpage168
dc.identifier.issn2352-0124
dc.identifier.scopus2-s2.0-85111847914
dc.identifier.scopusqualityQ1
dc.identifier.startpage158
dc.identifier.urihttps://doi.org/10.1016/j.istruc.2021.07.075
dc.identifier.urihttps://hdl.handle.net/11501/1170
dc.identifier.volume34
dc.identifier.wosWOS:000701894800007
dc.identifier.wosqualityQ1
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.language.isoen
dc.publisherElsevier Science Inc
dc.relation.ispartofStructures
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.subjectBuilding Importance Factor
dc.subjectPerformance Evaluation
dc.subjectResponse History Analyses
dc.subjectPush-Over Analyses
dc.subjectSeismicity
dc.subjectPerformance-Based Design
dc.titleEffect of building importance factor on seismic performance of rc frame type shopping malls subjected to pulse-like records
dc.typeArticle

Dosyalar

Orijinal paket
Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
Tam Metin / Full Text
Boyut:
5.76 MB
Biçim:
Adobe Portable Document Format