Enhancing efficiency in Peltier-cooled atmospheric water harvesting: a mathematical modeling and experimental study

dc.contributor.authorHeidarnejad, Parisa
dc.contributor.authorSulukan, Egemen
dc.contributor.authorDedecan, Abdullah
dc.contributor.authorKöse, Ali
dc.contributor.authorYıldırım, Furkan
dc.date.accessioned2026-01-05T08:59:45Z
dc.date.available2026-01-05T08:59:45Z
dc.date.issued2026
dc.departmentFakülteler, Mühendislik Fakültesi, Makine Mühendisliği Bölümü
dc.departmentMeslek Yüksekokulu, Gedik Meslek Yüksekokulu, Makine Programı
dc.descriptionIstanbul Gedik University Scientific Research Projects Coordination Unit (BAP) ; GDK202308-26
dc.description.abstractWater scarcity is one of the biggest global challenge, threatening current generation and necessitating alternative solutions. Among various technologies, atmospheric water harvesting systems offer a viable solution. The objective of this study is to present and assess an innovative geometry for Peltier-cooled atmospheric water harvesting system intended to improve drinkable water production through enhancing both mixing and heat transfer in the cold-side extended surfaces. The initial section of this study involves mathematical modeling. Findings of modeling section, illustrate an output of 1.97 L/day under conditions of 84.8% relative humidity and an ambient temperature of 32°C. The second section involves the design, fabrication, and performance evaluation of the system. The experimental observations indicate a water generation of 1.97 L/day in Test 1 (84.8% relative humidity, 32˚C), 1.63 L/day in Test 2 (85.8% relative humidity, 24.2˚C), 1.45 L/day in Test 3 (79% relative humidity, 25.4˚C), 1.29 L/day in Test 4 (76% relative humidity, 30˚C), and 1.13 L/day in Test 5 (69% relative humidity, 22.5˚C). These findings demonstrates the significant impact of environmental factors on the system's water generation performance. Moreover, novel geometry of the air inlet and exit channels improved the effectiveness of the water harvesting of the prototype across all test scenarios when compared with results reported in the literature. The outputs derived from modeling and experimental analysis, exhibit a strong correlation, thereby validating the model and highlighting the capability of the proposed system as a sustainable approach to global water scarcity problems.
dc.identifier.doi10.1016/j.tsep.2025.104411
dc.identifier.govdochttps://doi.org/
dc.identifier.issn2451-9049
dc.identifier.scopus2-s2.0-105025115952
dc.identifier.scopusqualityQ1
dc.identifier.urihttps://doi.org/10.1016/j.tsep.2025.104411
dc.identifier.urihttps://hdl.handle.net/11501/2588
dc.identifier.volume69
dc.identifier.wosWOS:001648865900001
dc.identifier.wosqualityQ1
dc.indekslendigikaynakScopus
dc.indekslendigikaynakWeb of Science
dc.institutionauthorSulukan, Egemen
dc.institutionauthorDedecan, Abdullah
dc.institutionauthorKöse, Ali
dc.institutionauthorYıldırım, Furkan
dc.institutionauthorid0000-0003-1138-2465
dc.institutionauthorid0000-0002-0426-5159
dc.institutionauthorid0009-0003-4001-9291
dc.language.isoen
dc.publisherElsevier Ltd
dc.relation.ispartofThermal Science and Engineering Progress
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.relation.tubitakinfo:eu-repo/grantAgreement/TUBITAK/SOBAG/1919B012324368
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectAtmospheric Water Harvesting
dc.subjectPeltier Modules
dc.subjectThermoelectric Cooler
dc.subjectWater Scarcity
dc.titleEnhancing efficiency in Peltier-cooled atmospheric water harvesting: a mathematical modeling and experimental study
dc.typeArticle

Dosyalar

Orijinal paket
Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
Tam Metin / Full Text
Boyut:
5.92 MB
Biçim:
Adobe Portable Document Format
Lisans paketi
Listeleniyor 1 - 1 / 1
Kapalı Erişim
İsim:
license.txt
Boyut:
1.17 KB
Biçim:
Item-specific license agreed to upon submission
Açıklama: